Seattle Data Center

Our data center infrastructure is engineered to optimize energy efficiency, from a single cabinet to your own dedicated modules. The New Jersey Campus offers cabinets, high-density cabinets, cages, suites, and modules.

RAISED FLOOR

Size – up to 42U
Private cabinets with individually set combination locks on traditional 36” raised floor

RACK

Size – Up to 47U
Power – Up to 30kW
Contract – Term 1 to 10 years

HALF MODULE

Size – Up to 8 Racks
Power – Up to 100kW
Dedicated – Security

D-MODULE

Size – Up to 18 Racks
Power – Up to 180kW
Dedicated – Cooling, power, fire suppression, security.

DS MODULE

Size – Up to 50 Racks
Power – Up to 360kW
Dedicated – Cooling, power, fire suppression, security.

A Data Center Engineered For Your Staged Growth And To Your Technical Specification.

We take a very different approach to the typical data center. We offer our customers the opportunity to utilize staged solutions that they require now, with a path and the availability for growth.


Site Specifications
  • 20,000 sq. ft. data center
  • Structural design built to meet Seismic Zone 3 Essential Facilities
  • I8-in. raised flooring
  • Seismically braced cabinets (one-ton capacity each)
  • UPS systems utilize seismic isolation bases
  • Independent water wells as backup water sources
  • Pre-action dry pipe sprinkler system with VESDA
  • Airside economization
  • AWS Direct Connect available for hybrid connectivity
  • Purpose-built for disaster survivability and operational continuity
  • First-in-line emergency support contracts are in place for power and refueling services
  • I0MW of power delivered via 2N infrastructure to ensure uninterrupted power delivery across four separate utility feeds
  • Available independent water source for continuous cooling
  • Diverse and redundant I0G connectivity designed for independence from the main regional telecom carrier hotel with routes south and west of Seattle
  • Private I0G diverse path and carrier ring to Spokane
  • Technologies, processes, and people to meet stringent physical security needs for any compliance or regulatory requirements
  • Prime downtown location for the downtown business corridor

Module Capacity
  • Total Slots – 4032

Access Control
  • 24x7x365 on-site personnel
  • SSAE-I6 SOC 1 Type II and SOC 2 Type II; HIPAA ATI0I Report on Compliance; GLBA ATI0I Report on Compliance; PCI Attestation of Compliance on Colocation Services
  • 24×7 on-site security guards
  • Dual factor authentication (card key and biometric)
  • CCTV surveillance with 90-day retention

Cooling Systems
  • Cooling – Water cooled chillers (4,510 tons)
  • Piping – Welded, bi-directional design
  • Leak Detection – Spot leak detection inside modules

Power Systems
  • I0.5MW of utility power
  • Onsite fuel capacity of more than 70,000 gallons
  • N+I power delivery systems (UPS/generator)
  • Multiple, redundant backup diesel generators on standby
  • Generators tested bi-weekly; routinely run at full load

Telecommunications
  • On-Net Carrier’s neutral network services, multiple service provider’s and product offering
  • AT&T
  • Bell Canada
  • Century Link
  • Comcast
  • Cogent
  • Frontier
  • Integra
  • Internap
  • Level 3
  • TW Telecom
  • Verizon
  • Wave Business
  • XO Communications
  • Zayo

Certifications
  • UTI Tier III Design Certified – Data Center 1 and Data Center 2
  • SOC1 Type 2
  • SOC2 Type 2

Network
  • Carrier-neutral connectivity
  • Connectivity diversity through Westin carrier hotel and non-Westin alternative path
  • National private, redundant and diverse path I0G connectivity
  • Private I0G fiber ring to Spokane facilities